I don’t know why this is such a hard combo to meet, but I can’t seem to find anything that suits. I assume there’s enterprise gear that would meet these points, but I’m not sure where to start.
POE is for running a half dozen POE cameras, 3x WIFI6 WAPs, Home Assistant Yellow. I could get away with running a separate POE switch if not for the WAPs (looking at the TP-Link AX11000’s which are 10GbE). I could buy a UniFi XG 6 POE for just the WAPs and use another regular POE switch to give me enough ports, but that’s just getting messy.
The ideal is to have a high density 10GbE managed switch that I can use for both my regular gear and POE gear (I have 20 ports to connect out to plus gear I might run in the rack). If the Unifi XG Enterprise had POE it would be perfect.
Mine is pretty darn quiet 🤷♂️
Actually it’s quieter than my hp procurve and my Plex server.
You’ll want to make sure the 6610 is flashed, configured and running both power supplies. Out of the box it runs at max speed without configuration and if it’s missing a PSU it will max the PSU fan to keep the internals cool.
Strange. Running it exactly like that. Any ressource for tweaking with the fan config?
Run “dm fan”
Here’s mine
As well as “show chassis”
Here’s mine as well
The stack unit 1 chassis info:
Power supply 1 (AC - PoE) present, status ok
Model Number: 23-0000142-02
Serial Number: 9FK
Firmware Ver: A
Power supply 1 Fan Air Flow Direction: Front to Back
Power supply 2 (AC - PoE) present, status ok
Model Number: 23-0000142-02
Serial Number: 91G
Firmware Ver: A
Power supply 2 Fan Air Flow Direction: Front to Back
Fan 1 ok, speed (auto): [[1]]<->2
Fan 2 ok, speed (auto): [[1]]<->2
Fan controlled temperature: 61.5 deg-C
Fan speed switching temperature thresholds:
Speed 1: NM<----->76 deg-C
Speed 2: 71<-----> 80 deg-C (shutdown)
Fan 1 Air Flow Direction: Front to Back
Fan 2 Air Flow Direction: Front to Back
MAC 1 Temperature Readings:
Current temperature : 49.0 deg-C
MAC 2 Temperature Readings:
Current temperature : 56.5 deg-C
CPU Temperature Readings:
Current temperature : 61.5 deg-C
sensor A Temperature Readings:
Current temperature : 50.5 deg-C
sensor B Temperature Readings:
Current temperature : 53.5 deg-C
sensor C Temperature Readings:
Current temperature : 39.5 deg-C
stacking card Temperature Readings:
Current temperature : 53.5 deg-C
Warning level…: 77.0 deg-C
Shutdown level…: 80.0 deg-C
Amazing, thank you. But how do I set values for it?