I am building a NAS in RAID 1 (Mirror) mode. Should I buy 2 of the same drive from the same manufacturer? or does it not matter so much?

  • vegivamp@feddit.nl
    link
    fedilink
    English
    arrow-up
    51
    arrow-down
    3
    ·
    1 year ago

    Quite the opposite. Use drives from as many different manufacturers as you can, especially when buying them at the same time. You want to avoid similar lifecycles and similar potential fabrication defects as much as possible, because those things increase the likelihood that they will fall close to each other - particularly with the stress of rebuilding the first one that failed.

    • duncesplayed@lemmy.one
      link
      fedilink
      English
      arrow-up
      25
      arrow-down
      3
      ·
      edit-2
      1 year ago

      To the best of my knowledge, this “drives from the same batch fail at around the same time” folk wisdom has never been demonstrated in statistical studies. But, I mean, mixing drive models is certainly not going to do any harm.

      • Hopfgeist@feddit.de
        link
        fedilink
        English
        arrow-up
        11
        ·
        1 year ago

        mixing drive models is certainly not going to do any harm

        It may, performance-wise, but usually not enough to matter for a small self-hosting servers.

        • TheWoozy@lemmy.world
          link
          fedilink
          English
          arrow-up
          7
          arrow-down
          1
          ·
          1 year ago

          I wouldn’t mix 5400 rpm drives with 7200 rpm drives, but if the rpm & sizes are the same, there won’t be any measurable performance loss.

      • Overspark@feddit.nl
        link
        fedilink
        English
        arrow-up
        8
        arrow-down
        1
        ·
        1 year ago

        If everything went fine during production you’re probably right. But there have definitely been batches of hard disks with production flaws which caused all drives from that batch to fail in a similar way.

      • SupraMario@lemmy.world
        link
        fedilink
        English
        arrow-up
        3
        ·
        1 year ago

        I know it’s only what I’ve experienced but I’ve been on a 2 weeks of hell from emc drives failing at the same time because dell didn’t change up serials. Had 20 raid drives all start failing within a few days of each other and all were consecutive serials.

    • empireOfLove@lemmy.one
      link
      fedilink
      English
      arrow-up
      12
      ·
      1 year ago

      If I had a dollar for every time rebuilding a RAID array after one failed drive caused a second drive failure in the array in less than 24 hours… I’d probably buy groceries for a week.

        • empireOfLove@lemmy.one
          link
          fedilink
          English
          arrow-up
          3
          ·
          1 year ago

          Yup. Same age, same design, same failures… and array rebuilds are super intense workloads that often force a lot of random reads and run the drive at 100% load for many hours.

        • teawrecks@sopuli.xyz
          link
          fedilink
          English
          arrow-up
          2
          ·
          1 year ago

          I’ve heard just in general. The resilvering process is hard on all the remaining drives for an extended period of time.

          • Avid Amoeba@lemmy.ca
            link
            fedilink
            English
            arrow-up
            1
            ·
            1 year ago

            So you’re saying I should be running RAIDz2 instead of RAIDz1? You’re probably right. 😂

            • teawrecks@sopuli.xyz
              link
              fedilink
              English
              arrow-up
              2
              ·
              1 year ago

              I made that switch a few years ago for that reason.

              That said, as the saying goes, RAID is not a backup, it should never be the thing that stands between you having and losing all your data. RAID is effectively just one really dependable hard drive, but it’s still a single point of failure.

              • Avid Amoeba@lemmy.ca
                link
                fedilink
                English
                arrow-up
                1
                ·
                edit-2
                1 year ago

                So you’re saying I should be running JBOD with backups instead of RAIDz1? You’re probably right. 🤭

                • teawrecks@sopuli.xyz
                  link
                  fedilink
                  English
                  arrow-up
                  1
                  ·
                  1 year ago

                  As long as you’re ok with it being way less dependable, and having to rebuild it from scratch more often 😉.

      • teawrecks@sopuli.xyz
        link
        fedilink
        English
        arrow-up
        1
        ·
        1 year ago

        I don’t know if you’re talking about the sample of cases you’ve personally witnessed, or the population of all NASes in the world. If the former, that sounds significant. If the latter, it sounds like it’s probably not something to worry about.